Ratto Norbin Kit Elisa (A5508)

$630
Spese di spedizione
Tempi di consegna
7-10 Giorni lavorativi
Telefono
+1 (314) 370-6046
Lun - Ven, 8:00 - 16:00 AST
E-mail
orders@antibodies.com
Nome
Rat Norbin ELISA Kit
Descrizione
Rat Norbin ELISA Kit is a sandwich (quantitative) Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat Norbin in tissue homogenates or other biological fluids.
Tipo di kit
Sandwich (quantitative)
Principio di kit
Rat Norbin ELISA Kit employs the Sandwich Enzyme Immunoassay (ELISA) technique for the quantitative measurement of rat Norbin in rat. An antibody specific for Norbin has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Norbin present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Norbin Antibody, which binds the captured Norbin present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and Avidin conjugated to Horseradish Peroxidase (Avidin-HRP) is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Norbin captured in each well. The concentration of Norbin can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Piattaforma
Pre-coated Microplate (12 x 8 well strips)
Tipo di rilevamento
Colourmetric
Instrument
Colorimetric Microplate Reader
Tipo di campione
Tissue homogenates or other biological fluids.
Sensibilità
0.055 ng/ml
Campo di rilevamento
0.156-10 ng/ml
Tempo del kit
1 - 4.5 Hours
Reattività
Rat
Recovery
Sample Type n Range Average
Serum 5 80% - 102% 91%
EDTA Plasma 5 81% - 100% 90%
Heparin Plasma 5 80% - 89% 84%
Linearity
Sample Type 1:2 1:4 1:8 1:16
Serum (n=5) 87-91% 87-107% 74-101% 92-97%
EDTA Plasma (n=5) 90-105% 84-101% 90-101% 79-108%
Heparin Plasma (n=5) 84-95% 92-105% 82-105% 89-91%
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Note generali
Information online is representative. Always refer to the Product Manual inside the kit.
Conservazione
Store at +4°C. Do not use past expiration date!
Dichiarazione di non responsabilità
Questo prodotto è solo per uso di ricerca. Non è inteso per uso diagnostico o terapeutico.
Inizio pagina