Maiale Testosterone Kit Elisa (A327150)

$582
Spese di spedizione
Tempi di consegna
7-10 Giorni lavorativi
Telefono
+1 (314) 370-6046
Lun - Ven, 8:00 - 16:00 AST
E-mail
orders@antibodies.com
Nome
Porcine Testosterone ELISA Kit
Descrizione
Porcine Testosterone ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of porcine Testosterone in serum and plasma.
Tipo di kit
Competitive (quantitative)
Principio di kit
Porcine Testosterone ELISA Kit (A327150) employs the competitive enzyme immunoassay technique for the quantitative measurement of porcine Testosterone in serum and plasma. The 96-well microtiter plate has been pre-coated with Testosterone antigen. During the incubation, Testosterone present in the samples or standards competes with the fixed amount of immobilized Testosterone for binding sites on the Biotinylated Anti-Testosterone Antibody. The more Testosterone present in a sample or standard, the less Biotinylated Anti-Testosterone Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Testosterone Antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Testosterone present in each sample or standard. The concentration of Testosterone can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Piattaforma
Pre-coated Microplate (12 x 8 well strips)
Tipo di rilevamento
Colormetric
Instrument
Colorimetric Microplate Reader
Tipo di campione
Serum and plasma.
Sensibilità
0.28 ng/ml
Campo di rilevamento
0.63-40 ng/ml
Tempo del kit
1h 30m
Reattività
Porcine
Reattività incrociata
No significant cross-reactivity or interference between porcine Testosterone and analogues was observed.
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Note generali
Information online is representative. Always refer to the Product Manual inside the kit.
Conservazione
Shipped at +4°C. Store short term at +4°C and long term at +4°C. Refer to Protocol Manual. Avoid freeze/thaw cycles.
Sinonimi
17b hydroxy 4 androsten 3 one, 17ß-hydroxyandrost-4-ene-3-one