This mouse IL-2 enzyme-linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific for mouse IL-2. Standards or samples are then added to the appropriate microtiter plate wells and incubated. Mouse IL-2, if present, will bind and become immobilized by the antibody pre-coated on the wells. The microtiter plate wells are thoroughly washed to remove unbound mouse IL-2 and other components in the samples. A biotin-conjugated antibody preparation specific for mouse IL-2 is added to each well and incubated. The biotin labelled antibody will attach to the wells by binding to mouse IL-2 present in the standards/samples. After plate washing, other proteins, components and unattached biotin labelled antibody are removed. Then, avidin-horseradish peroxidase (HRP) conjugate is added to each well. Avidin has a very high affinity for biotin, thus, it links the tracer (HRP) sturdily to the biotin conjugated antibody. The wells are thoroughly washed to remove all unbound avidin-HRPconjugate and aTMB(3,3'5,5' tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only the wells that contain mouse IL-2 will exhibit a change in colour. The extent of colour change is proportional to the quantity of mouse IL-2 present in the standards/samples. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the colour change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. In order to measure the concentration of mouse IL-2 in the samples, this kit contains two calibration diluents (Calibrator Diluent I for serum/plasma testing and Calibrator Diluent II for cell culture supernatant/ urine testing). According to the testing system, the provided standard is diluted (2-fold) with the appropriate Calibrator Diluent and assayed at the same time as the samples. This allows the operator to produce a standard curve of Optical Density (O.D.) versus IL-2 concentration (pg/mL). The concentration of IL-2 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Piattaforma
Microplate
Tipo di rilevamento
Colorimetric
Tipo di campione
Serum, cell culture supernatant and other biological fluids.
Sensibilità
< 2.1 pg/ml
Campo di rilevamento
7.8-500 pg/ml
Tempo del kit
3h 30m
Reattività
Mouse
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Conservazione
Store at 2-8°C.
Sinonimi
Aldesleukin, IL 2, IL-2, IL2, IL2_HUMAN, Interleukin 2, Interleukin2, Involved in regulation of T cell clonal expansion, Lymphokine , OTTHUMP00000164090, POIL2, T cell growth factor, T-cell growth factor, TCGF
Dichiarazione di non responsabilità
Questo prodotto è solo per uso di ricerca. Non è inteso per uso diagnostico o terapeutico.