Umano Growth Hormone Kit Elisa (A33016)

$555
Spese di spedizione
Tempi di consegna
5-8 Giorni lavorativi
Telefono
+1 (314) 370-6046
Lun - Ven, 8:00 - 16:00 AST
E-mail
orders@antibodies.com
Nome
Human Growth Hormone ELISA Kit (High Sensitivity)
Tipo di kit
Sandwich (quantitative)
Principio di kit
This hGH enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific to hGH. Standards or samples are then added to the microtiter plate wells and incubated. After wash all wells, hGH if present, will bind to the antibody pre-coated on the wells. In order to quantitatively determine the amount of hGH present in the sample, a standardized preparation of horseradish peroxidase (HRP)-conjugated monoclonal antibody specific to hGH is added to each well to “sandwich” the hGH immobilized on the plate. The microtiter plate undergoes incubation, and then the wells are thoroughly washed to remove all unbound components. Next, a TMB (3,3', 5,5' Tetramethyl-benzidene) substrate solution is added to each well. This enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain hGH and enzyme-conjugated antibody will exhibit a change in colour. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the colour change is measured spectrophotometrically at a wavelength of 450 nm.

In order to measure the concentration of hGH in the sample; this Human hGH ELISA Kit includes a set of calibration standards (6 standards). The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density (O.D.) versus GH concentration (ng/mL). The concentration of hGH in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Piattaforma
Microplate
Tipo di rilevamento
Colorimetric
Tipo di campione
Serum
Sensibilità
< 0.1 ng/ml
Campo di rilevamento
0.1-12 ng/ml
Reattività
Human
Reattività incrociata
This assay exhibits no detectable cross-reaction with LH, hCG, TSH, Prolactin, and FSH.
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Conservazione
Store at 2-8°C.
Sinonimi
gH, GH-N, GH1, GHN, Growth hormone, Growth hormone 1, HGH, Pituitary growth hormone, Somatotropin, SOMA_HUMAN
Dichiarazione di non responsabilità
Questo prodotto è solo per uso di ricerca. Non è inteso per uso diagnostico o terapeutico.