Rat IgG2a Kit Elisa (A327113)

$682
Frais de livraison
Date de livraison
Livraison sous 7-10 jours ouvrables.
Téléphone
+1 (314) 370-6046
Lun - Ven, 8h - 16h AST
E-mail
orders@antibodies.com
Nom du produit
Rat IgG2a ELISA Kit
Description du produit
Rat IgG2a ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of rat IgG2a in serum, plasma, and other biological fluids.
Type de test
Sandwich (quantitative)
Principe du test
Rat IgG2a ELISA Kit (A327113) employs the sandwich enzyme immunoassay technique for the quantitative measurement of rat IgG2a in serum, plasma, and other biological fluids. An antibody specific for IgG2a has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the IgG2a present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-IgG2a Antibody, which binds the captured IgG2a present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of IgG2a captured in each well. The concentration of IgG2a can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Plate-forme
Pre-coated Microplate (12 x 8 well strips)
Méthode de détection
Colormetric
Instrument
Colorimetric Microplate Reader
Type d'échantillon
Serum, plasma, and other biological fluids.
Sensibilité
3.75 ng/ml
Gamme de detection
6.25-400 ng/ml
Durée du test
4h 30m
Reactivité
Rat
Réactivité croisée
No significant cross-reactivity or interference between rat IgG2a and analogues was observed.
Recovery
Sample Type n Range Average
Serum 8 86% - 98% 91%
EDTA Plasma 8 88% - 99% 93%
Cell Culture Media 8 88% - 100% 93%
Linearity
Sample Type 1:2 1:4 1:8 1:16
Serum (n=5) 95-111% 93-107% 91-106% 88-102%
EDTA Plasma (n=5) 91-104% 88-99% 86-100% 86-100%
Cell culture media (n=5) 90-103% 88-98% 90-103% 88-99%
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%