Souris Choline Acetyltransferase Kit Elisa (A5351)

$595
Frais de livraison
Date de livraison
Livraison sous 7-10 jours ouvrables.
Téléphone
+1 (314) 370-6046
Lun - Ven, 8h - 16h AST
E-mail
orders@antibodies.com
Nom du produit
Mouse Choline Acetyltransferase ELISA Kit
Description du produit
Mouse Choline Acetyltransferase ELISA Kit is a sandwich (quantitative) Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse Choline Acetyltransferase in tissue homogenates, cell lysates or other biological fluids.
Type de test
Sandwich (quantitative)
Principe du test
Mouse Choline Acetyltransferase ELISA Kit employs the Sandwich Enzyme Immunoassay (ELISA) technique for the quantitative measurement of mouse Choline Acetyltransferase in mouse. An antibody specific for Choline Acetyltransferase has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Choline Acetyltransferase present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Choline Acetyltransferase Antibody, which binds the captured Choline Acetyltransferase present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and Avidin conjugated to Horseradish Peroxidase (Avidin-HRP) is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Choline Acetyltransferase captured in each well. The concentration of Choline Acetyltransferase can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Plate-forme
Pre-coated Microplate (12 x 8 well strips)
Méthode de détection
Colourmetric
Instrument
Colorimetric Microplate Reader
Type d'échantillon
Tissue homogenates, cell lysates or other biological fluids.
Sensibilité
0.53 ng/ml
Gamme de detection
1.56-100 ng/ml
Durée du test
1 - 4.5 Hours
Reactivité
Mouse
Recovery
Sample Type n Range Average
Serum 5 80% - 102% 91%
EDTA Plasma 5 81% - 100% 90%
Heparin Plasma 5 80% - 89% 84%
Linearity
Sample Type 1:2 1:4 1:8 1:16
Serum (n=5) 87-91% 87-107% 74-101% 92-97%
EDTA Plasma (n=5) 90-105% 84-101% 90-101% 79-108%
Heparin Plasma (n=5) 84-95% 92-105% 82-105% 89-91%
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Notes générales
Information online is representative. Always refer to the Product Manual inside the kit.
Stockage
Store at +4°C. Do not use past expiration date!
Synonymes
Acetyl CoA choline O acetyltransferase, Acetyl CoA:choline O acetyltransferase, ChAT, CHOACTase, Choline acetylase, Choline O acetyltransferase, Choline O-acetyltransferase, CLAT_HUMAN, CMS1A, CMS1A2, EC 2.3.1.6, OTTHUMP00000019583, OTTHUMP00000019584
Avertissement
Ce produit est uniquement destiné à la recherche. Il n'est pas destiné à un usage diagnostique ou thérapeutique.

Produits alternatifs à Souris Choline Acetyltransferase Kit Elisa (A5351)

Haut