+1 (314) 370-6046 oderKontakt

Maus MCP2 Kit Elisa (A323240)

$595
Versandkosten
Vorlaufzeit
Lieferung in 7-10 Werktagen
Telefon
+1 (314) 370-6046
Mo bis Frei, 8am - 4pm AST
Email
orders@antibodies.com
Produktname
Mouse MCP2 ELISA Kit (Small Sample Volume)
Beschreibung
Mouse MCP2 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse MCP2 in serum, plasma, and other biological fluids. This ELISA kit only requires 25µl of sample volume(s).
Assay-Typ
Sandwich (quantitative)
Assay-Prinzip
Mouse MCP2 ELISA Kit (A323240) employs the sandwich Enzyme-Linked Immunoassay technique for the quantitative measurement of mouse MCP2 in serum, plasma, and other biological fluids. An antibody specific for MCP2 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the MCP2 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-MCP2 Antibody, which binds the captured MCP2 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of MCP2 captured in each well. The concentration of MCP2 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.
Plattform
Pre-coated Microplate (12 x 8 well strips)
Nachweismethode
Colormetric
Instrument
Colorimetric Microplate Reader
Probentyp
Serum, plasma, and other biological fluids.
Sensitivität
10.45 pg/ml
Detektionsbereich
31.25-2000 pg/ml
Testdauer
3h 30m
Reaktivität
Mouse
Kreuzreaktivität
No significant cross-reactivity or interference between mouse MCP2 and analogues was observed.
Recovery
Sample Type n Range Average
Serum 8 91% - 102% 97%
EDTA Plasma 8 92% - 104% 97%
Cell Culture Media 8 95% - 106% 100%
Linearity
Sample Type 1:2 1:4 1:8 1:16
Serum (n=5) 90% - 106% 87% - 100% 94% - 106% 85% - 97%
EDTA Plasma (n=5) 93% - 105% 94% - 108% 90% - 105% 92% - 105%
Cell Culture Media (n=5) 88% - 101% 83% - 96% 84% - 97% 86% - 101%
Precision
Intra-assay CV: < 8%, Inter-assay CV: < 10%
Lagerung
Shipped at +4°C. Store short term at +4°C and long term at +4°C/-20°C. Refer to Protocol Manual. Avoid freeze/thaw cycles.
Synonyms
C C motif chemokine 8, CCL 8, Ccl8, CCL8_HUMAN, Chemokine (C C motif) ligand 8, Chemokine ligand 8, HC14, MCP 2, MCP-2, MCP-2(6-76), Monocyte chemoattractant protein 2, Monocyte chemotactic protein 2, SCYA10, SCYA8, Small inducible cytokine A8, Small inducible cytokine subfamily A (Cys Cys) member 8, Small-inducible cytokine A8
Haftungsausschluss
Dieses Produkt ist nur für Forschungszwecke bestimmt. Es ist nicht für diagnostische oder therapeutische Zwecke bestimmt.

Alternative Produkte zum Maus MCP2 Kit Elisa (A323240)

Oben